Satel INTEGRA Manual de usuario

Busca en linea o descarga Manual de usuario para Monóxido de carbono (co) detectores Satel INTEGRA. Satel INTEGRA User manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 75
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Alarm Control Panel
Firmware version 1.08
GDAŃSK
integra_u_en 08/10
USER
MANUAL
Vista de pagina 0
1 2 3 4 5 6 ... 74 75

Indice de contenidos

Pagina 1 - Alarm Control Panel

Alarm Control Panel Firmware version 1.08 GDAŃSK integra_u_en 08/10 USER MANUAL

Pagina 2 - WARNING

User Manual INTEGRA 8 In case of the LCD keypad, the partitions indicated by the installer will be armed. In case of the partition keypad, the partit

Pagina 3

INTEGRA SATEL 9 Fig. 2. View of INT-KLCDS-GR keypad. Fig. 3. View of INT-KLCDK-GR keypad.

Pagina 4

User Manual INTEGRA 10 Display The keypads are provided with a 2x16 character display with backlighting. The backlighting mode is determined by the i

Pagina 5

INTEGRA SATEL 11 - GROUP (two green LEDs) – used in graphic mode functions to indicate which data set is currently displayed. The LEDs can show the

Pagina 6 - 2. ABOUT THIS MANUAL

User Manual INTEGRA 12 • Auto arming delay countdown (timer-controlled partitions) – a series of 7 sounds (of diminishing length). • Chime in LCD k

Pagina 7 - 5. INTEGRA CONTROL PANEL

INTEGRA SATEL 1351 Selected events 52 All events 6 Set time 7 Troubles 8 Outputs control 9 Service mode 0 Downloading 01 Start DWNL-RS 02 Finish DWNL

Pagina 8 - ONTROL PANEL PERFORMANCE

User Manual INTEGRA 14 installer so that pressing the key [1] will be required). The [*] key enables exiting the function without saving the changes

Pagina 9

INTEGRA SATEL 15Key Characters available after next keystroke 1 ! ? ' `  " { } $ % & @ \ ^ | # 1 2 a b c 2 3 d e f 3

Pagina 10 - 6.1 LCD KEYPADS

User Manual INTEGRA 16 4. as code Ç – performs function assigned to the arrow key (p. 46) 5. as code Å – performs function assigned to the arrow ke

Pagina 11 - INTEGRA SATEL

INTEGRA SATEL 17SATEL offers the following partition keypads for INTEGRA control panels: − INT-S-GR/INT-S-BL − INT-SK-GR These keypads differ by size

Pagina 12 - User Manual INTEGRA 10

WARNING In order to avoid any operational problems with the control panel, it is recommended that you become familiar with this manual before you sta

Pagina 13

User Manual INTEGRA 18 When all the LEDs are alternately blinking (from top to bottom), there is no communication between the keypad and the control

Pagina 14 - User Manual INTEGRA 12

INTEGRA SATEL 19Functions accessible from the keypad include: [CODE][#] arming and disarming of partition; alarm clearing; and/or execution of contr

Pagina 15

User Manual INTEGRA 20 4. change of the code has been blocked because another user "hit" this code at an attempt to change his own code. I

Pagina 16 - User Manual INTEGRA 14

INTEGRA SATEL 216.3.2 Operation in partition keypad mode with proximity card reader (INT-SCR) The device executes functions of the partition keypad,

Pagina 17

User Manual INTEGRA 22 – hold down the key for about 3 seconds – AUX (medical) alarm; – hold down the key for about 3 seconds – PANIC alarm. An

Pagina 18 - 6.2 PARTITION KEYPADS

INTEGRA SATEL 23The audible signaling may be replaced by blinking of the keys backlight PROG. The beeps will translate, respectively, into keypad bac

Pagina 19

User Manual INTEGRA 24 The keypad can also audibly signal the DELAY ACTIVATION TIME PROG. 6.4 CODE LOCKS SATEL offers the following code locks for t

Pagina 20 - User Manual INTEGRA 18

INTEGRA SATEL 25 Fig. 8. Code lock type INT-SZK-GR. The basic function of the code lock is to control access to the room where the door provided wi

Pagina 21

User Manual INTEGRA 26 6.5 PROXIMITY CARD AND DALLAS CHIP READER Using the card/chips activates control in the partition the reader is assigned to -

Pagina 22 - User Manual INTEGRA 20

INTEGRA SATEL 27• The service can add, edit and delete the object users, provided that the SERVICE CAN EDIT option has been enabled by the master us

Pagina 23

INTEGRA SATEL 1New features in firmware versions 1.07 and 1.08 System operation The new INT-CR proximity card arm/disarm device enables arming / disa

Pagina 24 - User Manual INTEGRA 22

User Manual INTEGRA 28 − DURESS – used in an emergency situation, when the user has been forced to enter the code. Using the code will trigger a sil

Pagina 25

INTEGRA SATEL 293. Click with your mouse pointer on the CARD / DALLAS button. The card/chip adding window will open. 4. Select the method of adding

Pagina 26 - 6.4 CODE LOCKS

User Manual INTEGRA 30 zone will be violated as long as the keyfob button is depressed) and a corresponding reaction of the control panel. A button/c

Pagina 27

INTEGRA SATEL 31Reading the serial number during transmission 1. Select from the list the device which is to receive the transmission containing ser

Pagina 28 - 6.6 CODES AND USERS

User Manual INTEGRA 32 6.9.3 Removing keyfob by means of LCD keypad 1. Start the REMOVE ABAX KEYFOB function ([service code][*] ÆMASTERS ÆNEW MASTE

Pagina 29 - 6.7 PREFIXES

INTEGRA SATEL 331. Click at the selected user in the column corresponding to the button/combination of buttons to which you want to assign the zone.

Pagina 30 - ROXIMITY CARDS/DALLAS CHIPS

User Manual INTEGRA 34 6.9.10 Configuring event generation rules by means of DLOADX program Enabling/disabling generation of events for particular k

Pagina 31 - 6.9 APT-100 KEYFOBS

INTEGRA SATEL 35which prevented arming has been in the meantime removed, the partition will be armed. Otherwise, the list of causes which prevent arm

Pagina 32 - User Manual INTEGRA 30

User Manual INTEGRA 36 2. Call the ARMING MODE function. 3. Using the S and T keys select one of the suggested arming modes and press [#]. 4. Call

Pagina 33

INTEGRA SATEL 37Note: The special armed modes, as described earlier, are also defined for timers. • partition arming control by means of a special z

Pagina 34 - User Manual INTEGRA 32

User Manual INTEGRA 2 CONTENTS 1. GENERAL...

Pagina 35

User Manual INTEGRA 38 messages into SMS messages, thus allowing the use of this form of notifying also in the other INTEGRA control panels. The numb

Pagina 36 - 6.10 SYSTEM ARMED MODE

INTEGRA SATEL 39Two long beeps follow receipt of an incorrect code. If the entered code is invalid, the control panel will signal it by two long beep

Pagina 37

User Manual INTEGRA 40 • The control panel is protected against any attempts to scan the code – after three consecutive attempts to get access to th

Pagina 38 - User Manual INTEGRA 36

INTEGRA SATEL 41Defer auto-arm postpone the auto-arming Set auto-arm d. set auto-arming postpone time Arming mode select arming mode Cancel 1st co

Pagina 39 - 6.11 ALARMS

User Manual INTEGRA 42 New prox. card add proximity card Rem. prox. card remove proximity card New DALLAS add DALLAS chip Remove DALLAS remove DA

Pagina 40 - 6.13 ANSWERING PHONE CALLS

INTEGRA SATEL 43Erase s.message erase service note Tests Partitions check current state of partitions Zones check current state of zones Supply vo

Pagina 41

User Manual INTEGRA 44 View cleared alarms The function is available, provided that the user has not viewed the violated zones. It makes it possible

Pagina 42 - 7. USER FUNCTIONS

INTEGRA SATEL 45Disarm (2codes) The function is available when at least one partition in the system requires entering two codes to be disarmed. After

Pagina 43

User Manual INTEGRA 46 Arming mode This function makes it possible to select a special mode of arming, which will allow the user to stay in the facil

Pagina 44 - UARDX program

INTEGRA SATEL 47Change prefix The function is available to the master, if the installer has allowed prefixes to be used in the system. The installer,

Pagina 45 - ESCRIPTION OF USER FUNCTIONS

INTEGRA SATEL 36.10 SYSTEM ARMED MODE...

Pagina 46 - User Manual INTEGRA 44

User Manual INTEGRA 48 4. Time not renewable – code, for which the validity time period is limited to the number of days specified when entering a n

Pagina 47

INTEGRA SATEL 49It is possible to plan the guard rounds only for one of the above situations (for example, when the partition is armed). Missing guar

Pagina 48 - User Manual INTEGRA 46

User Manual INTEGRA 50 • The installer may define a list of rights to be instantly assigned to the new user. The other rights, available but not inc

Pagina 49

INTEGRA SATEL 51inhibited (or unbypassed) will be displayed. Use the S and T keys to scroll through the list. Shown in the top right corner of the di

Pagina 50 - User Manual INTEGRA 48

User Manual INTEGRA 52 Events The function makes possible to scroll the list of events stored in the control panel memory. The events are given in th

Pagina 51

INTEGRA SATEL 53Selection of partitions influences the contents of the list displayed when viewing event types from 1 to 4 (event type numbers accord

Pagina 52 - User Manual INTEGRA 50

User Manual INTEGRA 54 For the timer to operate it is necessary to: 1. Start the ACTIVE function and enable it ( ). 2. Select operation mode: everyda

Pagina 53

INTEGRA SATEL 55GuardX IP – the function enables programming the address of the computer, on which the GUARDX program is installed. The address must

Pagina 54 - User Manual INTEGRA 52

User Manual INTEGRA 56 – zone tamper, – zone violation, s – tamper alarm memory, a – alarm memory, – zone OK. Supply voltages – the function

Pagina 55

INTEGRA SATEL 57Keypad name – the function shows on display the name of particular keypad (default or installer assigned). File in DLOADX – the funct

Pagina 56 - User Manual INTEGRA 54

User Manual INTEGRA 4 1. GENERAL Thank you for choosing the product offered by the SATEL Company. High quality, large number of functions and simple

Pagina 57

User Manual INTEGRA 58 The function can be started from LCD keypad, without entering of any code, by pressing successively the [8] and [#] keys PROG.

Pagina 58 - User Manual INTEGRA 56

INTEGRA SATEL 59SHUTTER UP. The current status of the outputs is indicated on the display next to the output name in the following way: - outputs i

Pagina 59

User Manual INTEGRA 60 8. CONFORMANCE TO CLC/TS 50131-3 REQUIREMENTS If the control panel has been configured in accordance with the requirements of

Pagina 60 - User Manual INTEGRA 58

INTEGRA SATEL 619. APPENDIX A List of messages displayed in keypad when viewing the troubles: OUT[n] trouble: [n] =1–4 – number of control panel out

Pagina 61

User Manual INTEGRA 62 Long viol. z.[n]: [n]=1–128 zone number No violat. z.[n]: [n]=1–128 zone number No AC exp.[n]: [n]=0–63 expander number

Pagina 62 - User Manual INTEGRA 60

INTEGRA SATEL 6310. APPENDIX B EXPLANATION OF SOME TECHNICAL TERMS All definitions apply to the alarm system based on the INTEGRA control panel. STAR

Pagina 63 - 9. APPENDIX A

User Manual INTEGRA 64 11. APPENDIX C This appendix contains typical descriptions of the operations to be carried out when calling some user function

Pagina 64 - User Manual INTEGRA 62

INTEGRA SATEL 65• using partition numbers – in the graphic mode described below. This is the mode for the user who exactly knows the numbers of part

Pagina 65 - 10. APPENDIX B

User Manual INTEGRA 66 Note: If only one partition is armed, it will be disarmed immediately after pressing the [#] key (and the end message will be

Pagina 66 - 11. APPENDIX C

INTEGRA SATEL 67Notes: • One-time bypassing (inhibiting) of the a.m. zones will be possible if they belong to partitions, which is not armed. • Per

Pagina 67

INTEGRA SATEL 5It is necessary to periodically carry out a functional test of the alarm system. Check that the control panel responds to violation of

Pagina 68

User Manual INTEGRA 68 [*] Return to the Zone bypasses submenu. [*] Exit the user function menu. Note: Zone bypass (inhibit) is cancelled after d

Pagina 69 - ÁZone bypasses

INTEGRA SATEL 6912. BRIEF DESCRIPTION OF OPERATING THE SYSTEM FROM KEYPAD lit – all partitions operated by

Pagina 70 - Isolate

User Manual INTEGRA 70 13. HISTORY OF THE MANUAL UPDATES Given below is a description of changes as compared with the manual for the control panel wi

Pagina 71 - ROUBLES

INTEGRA SATEL 71of a timer (p. 37, 54). • Supplemented the diagram showing user functions menu (p. 40). • Added information on the option to assign

Pagina 72 - ISTORY OF THE MANUAL UPDATES

User Manual INTEGRA 72 • Information on "ETHM-1 – DloadX" and "ETHM-1 – GuardX" functions has been added in description of "

Pagina 73

SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.eu

Pagina 74

User Manual INTEGRA 6 • answering phone calls (this function is protected with a separate code) which allow to: − inform the user on the system sta

Pagina 75

INTEGRA SATEL 7card arm/disarm devices, partition keypads, code locks, as well as proximity card / DALLAS chip readers. The LCD keypads and proximity

Comentarios a estos manuales

Sin comentarios