INTEGRA SATEL
11
- GROUP (two green LEDs) – used in graphic mode functions to indicate which data set is
currently displayed. The LEDs can show the number of zones or outputs, or indicate
the corresponding expander bus. (See: section SELECTION FROM THE MULTIPLE-CHOICE
LIST IN THE GRAPHIC MODE
).
LED
INDICATION
left side/upper right side/lower
DESCRIPTION
OFF OFF group 1; numbers 1–32 (n)
OFF ON group 2; numbers 33–64 (32+n)
ON OFF group 3; numbers 65–96 (64+n)
ZONES/
OUTPUTS
ON ON group 4; numbers 97–128 (96+n)
OFF OFF
first expander bus
bus 1 numbers (addresses) 0-31 (DEC)
system addresses 00–1F (HEX)
EXPANDER
BUSES
OFF ON
second expander bus
bus 2 numbers (addresses 0-31 (DEC)
system addresses 20–3F (HEX)
n – number of LCD keypad field
6.1.2 Audible signals in keypads
When using the keypad the following signals, characteristic of some situations, can be heard
PROG.
One long beep – refusal of arming - the zone, which shouldn't be violated at the time of
arming, is violated (PRIORITY option), there was a trouble with the battery, expander, or
keypad. The refusal includes all zones selected for arming. Also, warning of the system
failure - prior to arming.
Two long beeps – unknown code/card, exit function/menu, or unavailable function.
Three long beeps – the code is recognized, but the function called is not accessible
(for example, temporary partition blocking is activated or the user has no access to
partitions operated from the keypad).
Two short beeps – selection accepted – entering more detailed menu level.
Three short beeps – acknowledgement of arming or disarming.
Four short and one long beeps – acceptance of execution of the selected function.
Three pairs of short beeps – it is necessary to change the code (for example, another
user, when changing his code, indicated the combination of digits identical with that in the
given user code; the code validity is expiring).
Additionally, the following situations may be signaled:
Alarm in partition continuous beep.
Fire alarm – long beep every second.
Countdown of entry delay – 2 short beeps every second.
Note: The signaling of entry delay countdown by 2 short beeps refers to the LCD keypads
type INT-KLCD-GR/BL and INT-KLCDR-GR/BL with firmware in version 1.05, and to
the keypads type INT-KLCDL-GR/BL, INT-KLCDS-GR/BL and INT-KLCDK-GR with
firmware in version 6.05. In keypads with earlier firmware versions, the entry delay
countdown is signaled by short beeps every 3 seconds.
Countdown of exit delay – long beeps every 3 seconds, completed with a series of
short beeps (for 10 seconds) and a single long beep. The way of “exit delay" signaling
informs that the countdown is ending prior to arming.
Vista de pagina 12