INTEGRA SATEL
11
- GROUP (two green LEDs) – used in graphic mode functions to indicate which data set is
currently displayed. The LEDs can show the number of zones or outputs, or indicate
the corresponding expander bus. (See: section SELECTION FROM THE MULTIPLE-CHOICE
LIST IN THE GRAPHIC MODE
).
LED
INDICATION
left side/upper right side/lower
DESCRIPTION
OFF OFF group 1; numbers 1–32 (n)
OFF ON group 2; numbers 33–64 (32+n)
ON OFF group 3; numbers 65–96 (64+n)
ZONES/
OUTPUTS
ON ON group 4; numbers 97–128 (96+n)
OFF OFF
first expander bus
bus 1 numbers (addresses) 0-31 (DEC)
system addresses 00–1F (HEX)
EXPANDER
BUSES
OFF ON
second expander bus
bus 2 numbers (addresses 0-31 (DEC)
system addresses 20–3F (HEX)
n – number of LCD keypad field
6.1.2 Audible signals in keypads
When using the keypad the following signals, characteristic of some situations, can be heard
PROG.
• One long beep – refusal of arming - the zone, which shouldn't be violated at the time of
arming, is violated (PRIORITY option), there was a trouble with the battery, expander, or
keypad. The refusal includes all zones selected for arming. Also, warning of the system
failure - prior to arming.
• Two long beeps – unknown code/card, exit function/menu, or unavailable function.
• Three long beeps – the code is recognized, but the function called is not accessible
(for example, temporary partition blocking is activated or the user has no access to
partitions operated from the keypad).
• Two short beeps – selection accepted – entering more detailed menu level.
• Three short beeps – acknowledgement of arming or disarming.
• Four short and one long beeps – acceptance of execution of the selected function.
• Three pairs of short beeps – it is necessary to change the code (for example, another
user, when changing his code, indicated the combination of digits identical with that in the
given user code; the code validity is expiring).
Additionally, the following situations may be signaled:
• Alarm in partition – continuous beep.
• Fire alarm – long beep every second.
• Countdown of entry delay – 2 short beeps every second.
Note: The signaling of entry delay countdown by 2 short beeps refers to the LCD keypads
type INT-KLCD-GR/BL and INT-KLCDR-GR/BL with firmware in version 1.05, and to
the keypads type INT-KLCDL-GR/BL, INT-KLCDS-GR/BL and INT-KLCDK-GR with
firmware in version 6.05. In keypads with earlier firmware versions, the entry delay
countdown is signaled by short beeps every 3 seconds.
• Countdown of exit delay – long beeps every 3 seconds, completed with a series of
short beeps (for 10 seconds) and a single long beep. The way of “exit delay" signaling
informs that the countdown is ending prior to arming.