User Manual INTEGRA 16
4. as code Ç – performs function assigned to the arrow key (p. 46)
5. as code Å – performs function assigned to the arrow key
6. as code Æ – performs function assigned to the arrow key
7. as code È – performs function assigned to the arrow key
8. open door (entry) – controls the electromagnetic door lock (generates a USER ACCESS
event)
9. open door (exit) – controls the electromagnetic door lock (generates a USER EXIT event)
10. 2 long sounds – signals reading of the card code
11. 1 short beep – signals that the card code has been read
Notes:
• Selecting the function 2 or 3 to be started by PRESENT CARD will block access to the HOLD
CARD
.
• The 8 and 9 functions require that the installer select the door to be opened by the keypad.
It is possible to control any door handled by the system (i.e. opened by code locks,
partition keypads or expanders of proximity card readers).
• Two long beeps can also mean readout of a card with unknown code.
• Readout of an unknown (wrong) code, if repeated three times, may generate a panel
recorded event or an alarm PROG. It can also block the reader in the keypad for 90 sec.
6.2 PARTITION KEYPADS
Fig. 4. INT-S-GR/INT-S-BL partition keypad.