INTEGRA SATEL
19
Functions accessible from the keypad include:
[CODE][#] arming and disarming of partition; alarm clearing; and/or execution of control
function,
[CODE][
*
] control of module on-board relay (e.g. electromagnetic door lock opening) can
also be used for disarming (if the partition was armed, and the relay will not be
activated for the armed mode time) PROG.
Notes:
• If the given partition is armed, and the keypad is also used to operate the electromagnetic
door lock, then entering [CODE][
*
] will disarm the partition and open the door - unless the
partition is temporarily blocked.
• Entering [CODE][
*
] will not disarm the partition, if the option CODE + * DOES NOT DISARM is
enabled for the expander. Nevertheless, the door can be opened, if the option ACCESS IF
ARMED
is enabled in the expander.
The user who wants to start the above mentioned functions must have access to the given
partition as well as appropriate authority level. In addition, he must be authorized to use the
given keypad by the master user or by the installer (service).
Note: Entering a wrong (not recognize) code three times may:
− trigger an alarm PROG;
− block a keypad for 90 sec. After this time each next wrong code entering will block
the keypad PROG.
Functions accessible from the partition keypad without entering the password:
− press in turn the [0] and [#] keys – fully armed mode;
− press in turn the [1] and [#] keys – enabling the fully armed mode and bypassing zones
with enabled BYPASSED IF NO EXIT option;
− press in turn the [2] and [#] keys – armed without interior mode (stay);
− press in turn the [3] and [#] keys – armed without interior and without entry delay mode
(stay, delay 0);
− press and hold down the (INT-S-GR / INT-S-BL) or (INT-SK-GR) keys for
approx. 3 seconds – FIRE alarm;
− press and hold down the (INT-S-GR / INT-S-BL) or (INT-SK-GR) keys for
approx. 3 seconds – AUX (medical) alarm;
− press and hold down the
(INT-S-GR / INT-S-BL) or (INT-SK-GR) keys for
approx. 3 seconds – PANIC alarm.
Another function of the partition keypad is the option of code change by the user PROG.
The user code change is performed as follows:
1. Press and hold down (for approx. 3 seconds) the key with digit 1 (labeled [ALARM] and
[ARMED] LEDs – red and green – start blinking alternately).
2. Enter the old CODE and press [#] (the [ALARM] and [TROUBLE] LEDs – red and
yellow – start blinking alternately).
3. Enter the new CODE and press [#] (the LEDs will stop blinking and the module will
generate a signal to confirm execution of the function).
The control panel cannot accept the change of code (which is signaled with two long beeps)
in the following four cases:
1. the new code is too short or too long (acceptable are codes 4 to 8 digits long);
2. the new code is too simple (the function of rejecting simple codes is activated);
3. the new code is identical with that of another user of the alarm system (someone else's
code was "hit"),