SATEL Installer Manual 29
When adding and removing the wireless devices, remember that the identification function
registers zones and outputs by groups of 8. Already after adding one wireless device which
takes up 1 zone, the control panel will reserve 8 zones in the system for wireless devices.
The LCD keypad makes it possible to select the zone to which that device will be assigned.
It is necessary to observe continuity, i.e. to avoid leaving gaps in the list, which will later
reduce the number of available zones in the system. You should also remember to maintain
continuity when removing wireless devices from the system. For example, if the devices
registered in the control panel occupy 9 items on the list, then 16 zones are reserved in the
system (2x8). After removal of the device which occupied item 7 on the list, there will still be
16 zones (2x8) reserved in the system for wireless devices, although 8 items are actually
taken up on the list of wireless devices (see: Table 4). In such a case, it is recommended that
the last devices be removed from the list and then added to the system again, so as to fill the
gap created in the list and reduce the number of zones in the system which are needlessly
reserved for wireless devices.
In case of devices which also occupy outputs along with zones, it is recommended that they
be added to the system first, so as not only to maintain the continuity of utilization of the
zones, but of the outputs as well. Shown in Table 4 is situation in which the first output of the
siren occupies place 8, and the second output - place 9. As a result, 16 outputs are reserved
in the system for wireless devices, though actually 2 are used (the eighth output in the first
group of 8 outputs and the first output in the second group of 8 outputs).
In some cases, gaps in the list of zones/outputs cannot be avoided. It concerns situations
when the number of zones/outputs actually used by the devices is not multiple of 8.
The radio communication has been designed so as to make possible operation of several
INTEGRA 128-WRL control panels and ACU-100 controllers when their operating ranges
overlap. Synchronization with the already working wireless systems is always carried out
when turning on the control panel /controller and after each operation of adding/removing the
supported devices. The synchronization is performed automatically. The number of wireless
devices with overlapping ranges depends on the RESPONSE PERIOD (see: PROGRAMMING
manual) and can be from 150 to 450. The higher the frequency of response, the less devices
can work with their ranges being mutually overlapped.
zones outputs
It. list of devices
No device No device
1 APD-100 detector 9 APD-100 detector 9 unused/unavailable
2 APD-100 detector 10 APD-100 detector 10
unused/unavailable
3 AMD-100 detector 11 AMD-100 detector 11
unused/unavailable
4 AMD-100 detector 12 AMD-100 detector 12
unused/unavailable
5 AMD-101 detector 13 AMD-101 detector 13
unused/unavailable
6 ^ 14 AMD-101 detector 14
unused/unavailable
7 15 unused/unavailable 15
unused/unavailable
8 ASP-105 siren
8
16 ASP-105 siren 16 ASP-105 siren
9 ^ 17 ASP-105 siren 17 ASP-105 siren
10 18 unused/unavailable 18
unused/unavailable
11 19 unused/unavailable 19
unused/unavailable
12 20 unused/unavailable 20
unused/unavailable
13 21 unused/unavailable 21
unused/unavailable
14 22 unused/unavailable 22
unused/unavailable
15 23 unused/unavailable 23
unused/unavailable
16
8
24 unused/unavailable 17
unused/unavailable
Table 4. Example of how wireless devices should not be registered. The system has
reserved 16 zones and 16 outputs for devices occupying 8 items.