SATEL Installer Manual 21
Information on powering detectors connected to expanders can be found in section
CONNECTING DEVICES TO EXPANDER BUS.
Figures 14, 15, 16 and 17 show various configurations of the detector connections. In the
presented examples, the detectors are powered from the AUX output. The signal from the
detector is supplied to the Z1 zone of the control panel. The Z2 zone in Figures 14, 15 and 16
has been programmed as type 9 (24H TAMPER). Separating the detector power supply ground
from the detector status signal ground eliminates the influence of the resistance of wires on
the detector status detection. Assuming that only one detector is connected to the cable and
the cable is not very long, the installation may be simplified by running one common single
wire for power supply ground and signal ground.
The NO, NC detectors in 2EOL configuration are connected in the same way, it is only
important to correctly indicate the type of detector connected the control panel (2EOL/NO or
2EOL/NC).
R
INTEGRA 128-WRL
NO TMP COM
12V
NO TMP
EOL/NO
Fig. 15. Exemplary connection of NO type detector in EOL configuration to control panel.
INTEGRA 128-WRL
R
NC TMP COM
12V
NC TMP
EOL/NC
Fig. 16. Exemplary connection of NC type detector in EOL configuration to control panel.