SATEL ETHM-1 Plus 21
7 Remote programming / operating of control panel via Ethernet
To enable communication with the control panel to be established from outside of the
local network, the module must have a permanent public address.
After three consecutive attempts to establish communication with the module using
an incorrect key, the module will stop responding for approx. 20 minutes to any
attempts to establish communication from the given IP address.
For information related to configuring the control panel by means of the DLOADX program via
the Ethernet network, please refer to the control panel programming manuals.
7.1 GuardX program
Communication between the GUARDX program and the control panel through the ETHM-1
Plus module can be established in two ways:
1. Initiating the connection from the G
UARDX program. This method enables connection with
the control panel to be established from any address.
2. Initiating the connection from the keypad (through the control panel). The alarm system
can be managed remotely only with the knowledge of the control panel user, from the
address programmed in the control panel.
Communication between the control panel and the GUARDX program can be
established, if the communication identifiers in the program and in the control panel
are identical (INTEGRA IDENTIFIER and GUARDX IDENTIFIER).
7.1.1 Configuring ETHM-1 Plus module
Program the key for data encryption during communication with the GUARDX program
(GUARDX/JAVA KEY).
Enable the GUARDX option, if the connection is to be initiated from the GUARDX program.
Enter the address of computer running GUARDX (GUARDX SERVER) program, if the
connection is to be initiated from the keypad (through the control panel).
Enter the number of TCP port which will be used for communication with the GUARDX
program, if it is to be different from 7091.
7.1.2 Configuring GUARDX program
Fig. 11. G
UARDX program: startup window.
In the startup window of G
UARDX program (Fig. 11), click on the "Configuration" button.
A window will be displayed, in which, in "TCP/IP" tab (Fig. 12), you should program:
ETHM-1 Plus module address, if communication is to be initiated from GUARDX program,
TCP port number (identical to that programmed in the module for communication
with GUARDX program – except where communication occurs through a network device
on which redirection to another port takes place),