USER MANUAL CA-10
6
States of control panel armed zones in LCD keypad
The LCD keypad can indicate in the bottom line of its display, either periodically or
permanently, the state of control panel armed zones. Given below are symbols which
may be displayed at the successive items (1–16) and their meaning.
- zone free (not violated)
- zone violated
S - violated tamper circuit of two-parameter zone
a - there was alarm from a zone (alarm memory)
s - there was tamper alarm from a two-parameter zone (tamper memory)
b - zone bypassed
These symbols may be changed with the service function of LCD keypad.
States signaled with sound
The signals produced to confirm the operation on the keypad
three short - system arming/disarming confirmation, alarm clearing, deactivating
output type 13 (BI switch),
two long - wrong access code, canceling a function or incorrect data for
a function,
three long - an attempt to arm the system when the zones with PRIORITY option
are violated or tampered (see: Arming),
four short, one long - correct user function completion, activating type 13 (BI
switch) output, or activating type 12 (MONO switch) output.
System events signaling
continuous signal - alarm condition,
intermittent signal - fire alarm,
one short signal every 3 seconds – entry delay time (or service mode),
one long signal every 3 seconds - exit delay time,
two short signals every 3 seconds - trouble,
five short - CHIME zone violated,
five long - DAY/NIGHT zone violated when the partition is disarmed, or counting
zone violated when the partition is armed.
The installer determines which events and in which keypads are to be signaled
acoustically.
User Access Codes
For everyday operation of the system it is necessary to know the user access code. The
control panel comes with one factory-set code (master user code) for each partition:
1234 for partition 1 (A),
2345 for partition 2 (B),
3456 for partition 3 (C),
4567 for partition 4 (D).
Additional 12 user access codes may be programmed for each partition (but no more
than 32 for the entire system). The code can be 4 to 6 digits long.