SATELLINE-M3-R3
Integration Guide, Version 1.6
16
3.6 Turn ON using command
When being in sleep mode, the receiver module will be automatically wake up after the CPU
senses a state change in the TD1 pin. The first data byte is lost because the CPU UART is shut
off, and is not able to read data.
To turn the module ON from modes sleep1 or sleep2
1) Issue a state change to DT1 (toggle pin (minimum pulse duration time 10 µs) or issue a
byte on the UART (for example 0x00))
2) Wait for “OK” -response from the module
3) Start communicating normally
Module will remain powered ON until a new sleep command is issued.
3.7 Turn OFF using command
Two control commands are available for putting the device into different states of power save
mode. (see SL-list).
3.8 Turn OFF using pin
The module can be shut down by driving ENA_IO line to <0.2V.
In the “OFF” state current consumption is only that of leakage current from a LDO (xx uA).
In this state all non parts off the module are powered down and all settings / state information
that are not stored in NVM is reset.
3.9 Restart
After startup the module can be restarted by issuing a SL command, upon which the module will
shut down all circuitry, and Reboot the CPU. (see SL-list)