Satel SATELLINE-M3-R3 Guía de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 27
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
SATELLINE-M3-R3
User Guide, Version 1.2
14
3 CHANGING PARAMETERS USING SL-COMMANDS
The controlling terminal device can change the configuration settings of the module. This is
accomplished with the help of SL-commands, which can be used during data transfer. SL-
commands can be used to change e.g. the frequency or addresses. It is also possible to ask the
radio modem to show current settings which are in use. The terminal device is either a PC or a
programmable logic (PLC) together with suitable (terminal) program.
3.1 SL-Commands
An SL-command is a continuous string of characters, which is separated from other data by
pauses which are equal or greater than time defined by Pause length parameter (default=3
characters) in the set-up. No extra characters are allowed at the end of an SL-command.
Serial interface settings are the same as in data transfer. SL-command is properly recognised
also in the case when the command string is terminated in <CR> (=ASCII character no. 13,
Carriage Return, 0x0d) or <CR><LF> (<LF> = ASCII char. no. 10, Line Feed, 0x0a). If
multiple SL commands are sent to the module, the next command can be given after receiving
the response ("Ok" or "Error") of the proceeding command. In addition, it is recommended to
implement a timeout to the terminal software for recovering the case when no response is
received from the radio modem.
The module will acknowledge all commands by returning an "OK" (command carried out or
accepted) or the requested value, or an "ERROR" (command not carried out or interpreted as
erroneous) message.
The SL-commands are listed in separate excel-document.
3.2 Operating modes
The modem has the following modes of operation:
Mode
Function
Description
Ready to
receive from RF
Search for sync
Module is searching for the start of a radio
transmission from the RF signal.
Receive data
The module has found a valid radio transmission
and is receiving data.
Safe mode
Mode is entered when a fault has been detected
and the device has been Rebooted. In safe mode
fault codes can be read from the modem.
Powersave
Sleep1
Will turn the modem into a state where it will hold
parts of the radio on, wakeup will take <5ms
Powersave
Sleep2
Will turn off the entire radio section and put CPU
into sleep mode. Consumption is lower, but
wakeup time is approx. <40ms.
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 26 27

Comentarios a estos manuales