CONVERTER FOR MONITORING STATION SMET-256 USER MANUAL Program version v1.07 smet256_en 04/11 ®
8 SMET-256 SATEL - subscriber defined, but there is currently no communication between the converter and the subscriber. 4.5 "UNREGISTERED"
SATEL SMET-256 9 4.7 "CONFIGURATION" WINDOW "Network" tab Fig. 5. The "Network" tab, "Configuration" windo
10 SMET-256 SATEL MAC control – select this field if the converter is to receive transmissions only from the devices with defined MAC numbers. It wi
SATEL SMET-256 11 Time server (NTP) – available, if the “Time synchronization” box is checked. In this field, enter the IP address of the time server
12 SMET-256 SATEL "Reporting" tab Fig. 8. The "Reporting" tab, "Configuration" window in the web browser (the window av
SATEL SMET-256 13 during communication. The identical server key must be entered in the settings for monitoring the subscriber's device. By defa
14 SMET-256 SATEL Receiver No. [1-9] – the field is available, if the SurGuard (MLR2/MLR2E) format has been selected. Enter in it the number of receiv
SATEL SMET-256 15 HTTP port – in this field, enter the number of network port to be used for opening the web browser. Values from 1 to 65535 can be e
16 SMET-256 SATEL Ping The parameters defined in this area will activate the function of ping command sending. Enabled – select the box to activate th
SATEL SMET-256 17 • The IP address and port defined in the "Program settings" tab may be different from the IP address of the converter pr
SATEL's goal is to continually improve the quality of its products, which may lead to alterations in their technic
SATEL sp. z o.o. ul. Schuberta 79 80-172 Gdańsk POLAND tel. + 48 58 320 94 00 [email protected] www.satel.pl
SATEL SMET-256 1 The SMET-256 converter is a solution offered to firms engaged in the monitoring of security alarm systems. It receives events sent t
2 SMET-256 SATEL Explanations for Fig. 1: 1 – LED indicators: PWR – power indicator – ON when power supply is connected ST – status indicator: − ON –
SATEL SMET-256 3 4. CONFIGURING THE CONVERTER Note: The device is only designed for working in the local computer networks (LAN). It cannot be direc
4 SMET-256 SATEL 4.2 SMET-256 SOFT PROGRAM 4.2.1 Configuration through RS-232 port Note: The converter default settings provide for operation in the
SATEL SMET-256 5 10 - failure indication icon. To see description of the failure hover the cursor over the icon. The grayed out icon means lack of f
6 SMET-256 SATEL Fig. 4. The „Subscribers” tab in web browser with some examples of subscriber definitions (the window available in SMET-256 Soft pro
SATEL SMET-256 7 Note: Be careful when selecting parameters to be entered in the fields "Test period" and "Number of missing tests&qu